홈 >                  	Term: Greenwell formula  
Greenwell formula
A formula used for calculating the thickness of tubbing: T = 0.03 + HD/50,000, where T is the required thickness of tubbing in feet, H is the vertical depth in feet, D is the diameter of the shaft in feet, and 0.03 is an allowance for possible flaws or corrosion.
- 품사: noun
 - 분야/도메인: 광업
 - 카테고리: 일반 광산; Mineral mining
 - Government Agency: USBM
 